Superclass (is-a): «abstract» System

Dielectric

Definition: «abstract» System that manages a chemical mixture used in a manufacturing process being performed at that piece of equipment.

Version Info

IntroducedDeprecatedUpdated
1.4  

Documentation

Description

For example, this could describe the dielectric system for an EDM process or the chemical bath used in a plating process.

Inherited from «abstract» System


Properties

NameTypeIntDepMultiplicityDescription
id ID1.11 unique identifier for the «abstract» Component.
name string1.10..1

name of the «abstract» Component.

When provided, «abstract» Component::name MUST be unique for all child «abstract» Component entities of a parent «abstract» Component.

nativeName string1.10..1 common name associated with «abstract» Component.
sampleInterval float1.20..1

interval in milliseconds between the completion of the reading of the data associated with the «abstract» Component until the beginning of the next sampling of that data.

This information may be used by client software applications to understand how often information from a «abstract» Component is expected to be refreshed.

The refresh rate for data from all child «abstract» Component entities will be the same as for the parent «abstract» Component element unless specifically overridden by another «abstract» Component::sampleInterval provided for the child «abstract» Component.

sampleRate float1.11.20..1 DEPRECATED in MTConnect Version 1.2. Replaced by «abstract» Component::sampleInterval.
uuid UUID1.10..1 universally unique identifier for the «abstract» Component.
coordinateSystemIdRef ID1.80..1 specifies the CoordinateSystem for this «abstract» Component and its children.


Back to top

Copyright © 2017-2026 Association for Manufacturing Technology (AMT). All rights reserved. MTConnect® is a trademark of AMT. Terms of Use.

MTConnect SysML Model V2.8