ControllerModeEnum

Version Info

IntroducedDeprecatedUpdated
1.0  

Enumeration Literals

NameIntDepUpdDescription
AUTOMATIC1.0 Controller is configured to automatically execute a program.
EDIT1.3 Controller is currently functioning as a programming device and is not capable of executing an active program.
FEED_HOLD1.21.3 axes of the device are commanded to stop, but the spindle continues to function.
MANUAL1.0 Controller is not executing an active program. It is capable of receiving instructions from an external source – typically an operator. The Controller executes operations based on the instructions received from the external source.
MANUAL_DATA_INPUT1.0 operator can enter a series of operations for the Controller to perform. The Controller will execute this specific series of operations and then stop.
SEMI_AUTOMATIC1.1 Controller is operating in a mode that restricts the active program from processing its next process step without operator intervention.