SampleEnum

Supertype: DataItemTypeEnum

Stereotypes: <<extensible>>

Version Info

IntroducedDeprecatedUpdated
1.0  

Enumeration Literals

NameIntDepUpdDescription
ACCELERATION1.0 positive rate of change of velocity.
ACCUMULATED_TIME1.2 accumulated time for an activity or event.
AMPERAGE1.01.6 strength of electrical current. DEPRECATED in Version 1.6. Replaced by AMPERAGE_AC and AMPERAGE_DC.
AMPERAGE_AC1.6 electrical current that reverses direction at regular short intervals.
AMPERAGE_DC1.6 electric current flowing in one direction only.
ANGLE1.0 angular position.
ANGULAR_ACCELERATION1.0 positive rate of change of angular velocity.
ANGULAR_DECELERATION1.7 negative rate of change of angular velocity.
ANGULAR_VELOCITY1.0 rate of change of angular position.
ASSET_UPDATE_RATE1.7 average rate of change of values for assets in the MTConnect streams. The average is computed over a rolling window defined by the implementation.
AXIS_FEEDRATE1.0 feedrate of a linear axis.
CAPACITY_FLUID1.5 fluid capacity of an object or container.
CAPACITY_SPATIAL1.5 geometric capacity of an object or container.
CONCENTRATION1.2 percentage of one component within a mixture of components.
CONDUCTIVITY1.2 ability of a material to conduct electricity.
CUTTING_SPEED1.5 speed difference (relative velocity) between the cutting mechanism and the surface of the workpiece it is operating on.
DECELERATION1.7 negative rate of change of velocity.
DENSITY1.5 volumetric mass of a material per unit volume of that material.
DEPOSITION_ACCELERATION_VOLUMETRIC1.5 rate of change in spatial volume of material deposited in an additive manufacturing process.
DEPOSITION_DENSITY1.5 density of the material deposited in an additive manufacturing process per unit of volume.
DEPOSITION_MASS1.5 mass of the material deposited in an additive manufacturing process.
DEPOSITION_RATE_VOLUMETRIC1.5 rate at which a spatial volume of material is deposited in an additive manufacturing process.
DEPOSITION_VOLUME1.5 spatial volume of material to be deposited in an additive manufacturing process.
DIAMETER1.6 dimension of a diameter.
DISPLACEMENT1.0 change in position of an object.
ELECTRICAL_ENERGY1.2 Wattage used or generated by a component over an interval of time.
EQUIPMENT_TIMER1.4 amount of time a piece of equipment or a sub-part of a piece of equipment has performed specific activities.
FILL_LEVEL1.2 amount of a substance remaining compared to the planned maximum amount of that substance.
FLOW1.2 rate of flow of a fluid.
FREQUENCY1.0 number of occurrences of a repeating event per unit time.
GLOBAL_POSITION1.01.1 position in three-dimensional space. DEPRECATED in Version 1.1.
HUMIDITY_ABSOLUTE1.6 amount of water vapor expressed in grams per cubic meter.
HUMIDITY_RELATIVE1.6 amount of water vapor present expressed as a percent to reach saturation at the same temperature.
HUMIDITY_SPECIFIC1.6 ratio of the water vapor present over the total weight of the water vapor and air present expressed as a percent.
LENGTH1.3 length of an object.
LEVEL1.11.2 level of a resource. DEPRECATED in Version 1.2. See FILL_LEVEL.
LINEAR_FORCE1.2 forcepush or pull on a mass which results in an acceleration. applied to a mass in one direction only.
LOAD1.0 actual versus the standard rating of a piece of equipment.
MASS1.2 mass of an object(s) or an amount of material.
OBSERVATION_UPDATE_RATE1.7 average rate of change of values for data items in the MTConnect streams. The average is computed over a rolling window defined by the implementation.
OPENNESS2.0 percentage open where 100% is fully open and 0% is fully closed.
ORIENTATION1.6 measured or calculated orientation of a plane or vector relative to a cartesian coordinate system.
PATH_FEEDRATE1.0 feedrate for the axes, or a single axis, associated with a Path component.
PATH_FEEDRATE_PER_REVOLUTION1.5 feedrate for the axes, or a single axis.
PATH_POSITION1.1 measured or calculated position of a control point associated with a Controller entity, or Path entity if provided, of a piece of equipment.
PH1.1 acidity or alkalinity of a solution.
POSITION1.0 measured or calculated position of a Component element as reported by a piece of equipment.
POWER_FACTOR1.2 ratio of real power flowing to a load to the apparent power in that AC circuit.
PRESSURE1.0 force per unit area measured relative to atmospheric pressure. Commonly referred to as gauge pressure.
PRESSURE_ABSOLUTE1.7 force per unit area measured relative to a vacuum.
PRESSURIZATION_RATE1.7 change of pressure per unit time.
PROCESS_TIMER1.4 amount of time a piece of equipment has performed different types of activities associated with the process being performed at that piece of equipment.
RESISTANCE1.2 degree to which a substance opposes the passage of an electric current.
ROTARY_VELOCITY1.2 rotational speed of a rotary axis.
SOUND_LEVEL1.2 sound level or sound pressure level relative to atmospheric pressure.
SPINDLE_SPEED1.01.2 rotational speed of the rotary axis. DEPRECATED in Version 1.2. Replaced by ROTARY_VELOCITY.
STRAIN1.2 amount of deformation per unit length of an object when a load is applied.
TEMPERATURE1.0 degree of hotness or coldness measured on a definite scale.
TENSION1.4 force that stretches or elongates an object.
TILT1.2 angular displacement.
TORQUE1.0 turning force exerted on an object or by an object.
VELOCITY1.0 rate of change of position of a Component.
VISCOSITY1.2 fluid’s resistance to flow.
VOLTAGE1.01.6 electrical potential between two points. DEPRECATED in Version 1.6. Replaced by VOLTAGE_AC and VOLTAGE_DC.
VOLTAGE_AC1.6 electrical potential between two points in an electrical circuit in which the current periodically reverses direction.
VOLTAGE_DC1.6 electrical potential between two points in an electrical circuit in which the current is unidirectional.
VOLT_AMPERE1.2 apparent power in an electrical circuit, equal to the product of root-mean-square (RMS) voltage and RMS current (commonly referred to as VA).
VOLT_AMPERE_REACTIVE1.2 reactive power in an AC electrical circuit (commonly referred to as VAR).
VOLUME_FLUID1.5 fluid volume of an object or container.
VOLUME_SPATIAL1.5 geometric volume of an object or container.
WATTAGE1.0 power flowing through or dissipated by an electrical circuit or piece of equipment.
X_DIMENSION1.6 dimension of an entity relative to the X direction of the referenced coordinate system.
Y_DIMENSION1.6 dimension of an entity relative to the Y direction of the referenced coordinate system.
Z_DIMENSION1.6 dimension of an entity relative to the Z direction of the referenced coordinate system.

Subclasses

NameIntDep
ConditionEnum1.1 

Back to top

Copyright © 2017-2026 Association for Manufacturing Technology (AMT). All rights reserved. MTConnect® is a trademark of AMT. Terms of Use.

MTConnect SysML Model V2.0