SensorConfiguration

Definition: configuration for a Sensor.

Version Info

IntroducedDeprecatedUpdated
1.2  

Documentation

Description

SensorConfiguration

Note: See Section Configuration Schema Diagrams for XML schema.

Properties

NameTypeIntDepMultiplicityDescription
CalibrationDate datetime1.20..1 Date upon which the sensor unitintelligent piece of equipment that manages the signals of one or more sensing elements and provides the measured values. was last calibrated.
CalibrationInitials string1.20..1 The initials of the person verifying the validity of the calibration data.
FirmwareVersion string1.21 Version number for the sensor unit as specified by the manufacturer.
NextCalibrationDate datetime1.20..1 Date upon which the sensor unitintelligent piece of equipment that manages the signals of one or more sensing elements and provides the measured values. is next scheduled to be calibrated.

Relations

NameTypeIntDepMultiplicityDescription
hasChannel Channel1.20..*
isSensorConfigurationOf Configuration1.20..1