Alarm

Supertype: Event

Definition: DEPRECATED: Replaced with CONDITION category data items in Version 1.1.0.

Version Info

| Introduced | Deprecated | Updated | |—:|—:|—:| | 1.0 | 1.1 | |

Inherited Properties

NameTypeIntDepMultiplicityDescription
resetTriggered ResetTriggeredEnum1.41.10..1

identifies when a reported value has been reset and what has caused that reset to occur for those DataItem entities that may be periodically reset to an initial value.

resetTriggered MUST only be provided for the specific occurrence of a DataItem reported in the MTConnectStreams Response Documentresponse document published by an MTConnect Agent in response to a current request or a sample request. when the reset occurred.

type EventEnum1.01.11

Properties

NameTypeIntDepMultiplicityDescription
type EventEnum (Only: ALARM)1.01.11
code AlarmCodeEnum1.01.11 type of alarm.
severity AlarmSeverityEnum1.01.11 severity of the alarm.
nativeCode string1.01.11 native code for the piece of equipment.
state AlarmStateEnum1.01.11 state of the alarm.
lang xslang1.01.10..1

specifies the language of the alarm text.

See IETF RFC 4646 (http://www.ietf.org/rfc/rfc4646.txt).


Back to top

Copyright © 2017-2026 Association for Manufacturing Technology (AMT). All rights reserved. MTConnect® is a trademark of AMT. Terms of Use.